Space Ballz Troubleshooting

Error Codes and other common issues

E- on SEG Display
An E- will show on a score SEG display when a ball score sensor (Mechanical) is stuck in the closed or activated position. The Error will score on the Score...
Thu, Feb 18, 2021 at 10:18 AM
Error 19
Check to make sure there is a ball in the upper acrylic structure. There should only be 1 ball being held in the upper structure.  If there is more than 1 ...
Fri, Sep 13, 2019 at 4:10 PM
Error 24 Bonus-Optic Sensor Error
On the Bonus Ball hook assembly there is an Optic sensor (1 inch by 1 inch board 3 wires) which tells the hook to go in the down or rest position when t...
Thu, Feb 18, 2021 at 10:18 AM
L- Error/Call Attendant
L- is a "Link Error"  Security thumb drive is not connecting because the computer is not booting up Gray ribbon cable is in the wrong position ...
Wed, Mar 31, 2021 at 11:23 AM
Coke Bottle/ Wrench Motor Malfunction and Adjustment Video
Motor Direction Board Check for 11.7v-12.2v Calibrate Motor Directional Board POT Switch (rotate completely counterclockwise then clockwise until LED ...
Wed, Mar 31, 2021 at 11:47 AM
Claw Malfunction and Wire Replacement Video
If Claw has issues opening and releasing balls and may get stuck with a double feed in the home position.  Check for 11.7v-12.2v at the Claw Solenoid Che...
Thu, Feb 18, 2021 at 10:43 AM
Space Ballz Hard Reset Video
https://www.youtube.com/watch?v=EartPi1bnuY
Wed, Feb 10, 2021 at 2:45 PM
Space Ballz Motor Direction Board Adjustment Video
Wed, Feb 10, 2021 at 2:49 PM
Space Ballz PC Troubleshooting Video
Wed, Feb 10, 2021 at 2:46 PM
SpaceBallz I/O Chart and Dip Switch Settings
Attached is the I/O Chart and Dip switch setting for SpaceBallz
Thu, Feb 18, 2021 at 10:21 AM